Inquiry
Form loading...
Products Categories
Featured Products
01

Coal gas detector for home LX-212AD

2021-07-05 08:21:52
Model LX-212AD gas detector has superior gas sensor with Japan technology.Double power supply 220V AC or 12V DC optional. It has sensitivity of 10% LEL. This gas leak detector suitable for detecting LPG(Butane, Propane)used in normal and mini gas bottles,detecting gas from piping system (city gas) and natural gas (Methane).  Green indicator is for power.Red light is alarm indication.   Besides visual alarm signal of red indicator, the gas detector provides audible signal of 85db alarm sound,reducing the risk of gas explosion and protect your family’s life and property safety. Gas detectors are widely used at home,restaurant,hospital,garage or oil factory.
view detail
01

Natural gas detector for home LX-212ADL

2021-04-29 11:26:45
Model LX-212ADL gas detector has superior gas sensor with Japan technology.Double power supply 220V AC or 12V DC optional. It has sensitivity of 10% LEL. This gas leak detector suitable for detecting LPG(Butane, Propane)used in normal and mini gas bottles,detecting gas from piping system (city gas) and natural gas (Methane).   Green indicator is for power.Red light is alarm indication. The gas detector has built-in relay and can be connected to system solenoid valve and fan.   Besides visual alarm signal of red indicator, the gas detector provides audible signal of 85db alarm sound,reducing the risk of gas explosion and protect your family’s life and property safety. Gas detectors are widely used at home,restaurant,hospital,garage or oil factory.
view detail
01

Gas Detector LX-212ADS

2021-07-22 19:13:52
Gas Detector Model #: LX-212AS Technical Parameters 1. Power supply: 220VAC 2. Power consumption: 1.7W 3. Alarm sonority: ≥85dB 4. Sensitivity: 10% LEL 5. Working temperature: -10℃--+50℃ 6. Working humidity: ≤95%RH 7. Type of gas sensed: a) + LPG (Butane, Propane) used in normaland mini gas bottles b) + Gas from piping system (city gas) and natural gas(Methane) 8. Can be equipped with solenoid valve 9. Product size: 11.5x7.2 x4.4cm Packing Data QTY/CTN CARTON SIZE QTY/20GP 50pcs 55x25x28.5CM 35200pcs Parts Description  
view detail
01

CO And Gas Detector LX-214

2021-07-22 19:13:53
Technical Parameters 1. Power supply: 110VAC 2. Power consumption: 3.8W 3. Alarm sonority: ≥85dB 4. Sensitivity: 10% LEL 5. Working temperature: 4℃--38℃ 6. Working humidity: 25%--85%RH 7. Low voltage alarm: a sharp sound / 15s 8. Static indication: red LED light flash 1 time / 2s 9. CO sensitivity: a) at 70PPM, alarm within 60--240minutes b) at 150PPM, alarm within 10-50minutes c) at 400PPM, alarm within 4-15minutes 10. Product size: 15.5x9.7 x4.6cm Packing Data
view detail
01

Gas Detector LX-215

2021-07-22 19:13:54
Technical Parameters 1. Power supply: 220V / 110VAC 2. Power consumption: 1.7W 3. Alarm sonority: ≥85dB 4. Sensitivity: 10% LEL 5. Working temperature: -10℃--+50℃ 6. Working humidity: ≤ 95%R 7. Product size: 12.6x7.2 x4.6cm Packing Data
view detail
01

CO (Carbon Monoxide) Detector LX-202L

2021-07-22 19:13:56
Technical Parameters 1. Power supply: 24VDC 2. Static current: ≤7mA 3. Alarm current: ≤9mA 4. Alarm density: 400PPM 5. Working temperature: -10℃--+50℃ 6. Working humidity: 5%--95%RH 7. Can be connected with system 8. Product size: 10.9x10.9 x5.2cm Packing Data
view detail
01

Heat detector with battery LX-227AC/DC

2021-04-29 11:51:55
This heat detector is designed to detect ambient temperature. When ambient temperature reaches preset value or the temperature flare to rise,the buzzer will sound. The detector is suitable for industrial and civil building where there is explosive and combustible gas. *Model LX-227AC/DC can be connected with mains power(110-220V AC). The heat detector has a built-in 9V battery as backup power. It can work normally in the event of a power outage. *Explosionproof function,elegant shell,ceiling mounting easily in minutes *The heat detector is power saving.Static current is less than 100uA. Alarm current is 10-15mA.But alarm sonority is higher than 85db at 1meter distance.   *After installing and switching on power,the detector is in operation state.Led indicator flash every 30 seconds.When it detects the ambient temperature is higher than preset alarm value or the temperature flare up to rise,the buzzer will sound.   Installation method:Turn anti-clockwise the detector body and loosen the base.Install the base to installation position.Turn clockwise the body on base.When it is buttoned completely,you will hear”da”sound.
view detail
01

Stand alone heat detector with sound LX-227

2021-06-25 09:07:03
Model LX-227 is a stand alone heat detctor powered by 9V DC battery.This heat detector is designed to detect ambient temperature. When ambient temperature reaches preset value or the temperature flare to rise,the buzzer will sound. The detector is suitable for industrial and civil building where there is explosive and combustible gas. *Explosionproof function,elegant shell,ceiling mounting easily in minutes *Detecting method:rate of rise and reaching alarm temperature 65℃ *The heat detector is power saving.Static current is less than 100uA. Alarm current is 10-15mA.But alarm sonority is higher than 85db at 1meter distance.   *After installing and switching on power,the detector is in operation state.Led indicator flash every 30 seconds.When it detects the ambient temperature is higher than preset alarm value or the temperature flare up to rise,the buzzer will sound.   Installation method:Turn anti-clockwise the detector body and loosen the base.Install the base to installation position.Turn clockwise the body on base.When it is buttoned completely,you will hear”da”sound.
view detail
01

Sound and Photic Alarm LX-102A/B

2021-07-22 19:14:00
Technical Parameters 1. System voltage/current: 9V (sound) / 120mA 9V (flash) / 60mA 2. Operating temperature: 0℃--50℃ 3. Working humidity: <95% RH 4. Alarm sonority: ≥100dB 5. Indicator colour: red, orange, blue 6. Product size: 20.2x11.3 x7.1cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-102A  B 50pcs 60.5x40x42.5 14000
view detail
01

Sound and Photic Luxury Alarm LX-103

2021-07-22 19:14:00
Technical Parameters 1. Working voltage: 9V--12VDC / 24VDC 2. Current: ≤300mA 3. Alarm sonority: ≥100dB 4. Operating temperature: -10℃--+55℃ 5. Working humidity: 10%-90% RH 6. Anti-jamming intensity: 1V/m (frequency 20--1000MHZ) 7. Installation: clean, dry and non-vibration wall 8. Product size: 31.4x19.7 x7.5cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-103 10pcs 54x34x43 4900pcs
view detail
01

Fire alarm and manual alarm button combination LX-231A

2021-04-29 12:17:14
This fire alarm device is a combination of fire alarm siren and manual call point.The fire alarm is supplied independently by 9V DC battery. When pressing the button panel,the device will sound continuous alarm and light flashes at the same time to remind people to escape from fire. *Voltage:9V DC * Alarm current:100mA *Alarm sonority: ≥100db *Alarm time:30 minutes * Working temperature: -5℃ to+65℃ *Product size:31.4x19.7x9.6cm *Regular packing is each fire alarm is packed into a neutral white box, 10pcs/master carton,customized color box is available if clients have special demand. Practice fire safety: Expose everyone to the sound of the fire alarm in daily life and explain what the sound means and how to operate the fire alarm button if a fire occurs.Discuss in advance two exits from each room and an escape route to the outside from each exit.Teach them to crawl along the floor to stay below dangerous smoke,fumes and gases.Determine a safe meeting place in advance for all members outside the building. What to do in case of fire: 1. Do not be panic,stay calm. 2. Leave the building as quickly as possible.Touch doors to feel if they are hot before opening them.Use and alternate exit if necessary.Crawl along the floor to stay below dangerous smoke, and don’t stop to collect anything. 3. Meet a pre-arranged meeting place outside the building. 4. Call the fire department form outside the building. 5. Do not go back inside a burning building.Wait for the arrival of the fire department. Caution:Always turn off power at main fuse box or circuit breaker before taking troubleshooting action.Do not disconnect battery or AC power to quiet an unwanted alarm.This will remove your protection.Fan the air or open a window to remove smoker or dust.
view detail
01

Manual Call Point LX-232

2021-07-22 19:14:02
Technical Parameters 1. Max. voltage: 50V AC/DC 2. Max. current: 3A AC/DC 3. Battery: 23A/12V x 2 4. Working temperature: -10℃--+65℃ 5. Working humidity: 10%--90%RH 6. Alarm sonority: ≥85dB 7. Installation: indoor or dry occasion 8. Product size: 8.9x8.9 x5.3cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-232 50pcs 59x39.5x25 24300
view detail