01

Door Sensor Valve LX-306

2021-07-22 19:14:08
Technical Parameters 1. Switches: ①Normally Closed ②Normally Open ③Chang Over 2. Contact power: ①10W ②3W ③3W 3. Current of switches: ①0.5A ②0.2A ③0.2A 4. Beginning voltage: ①100V ②30V ③30V 5. Initial resistance: 200? 6. Action distance: 50-60mm Packing Data Qty./ctn Carton Size Qty./Container 17pcs 37.5X29.5X30cm 20ft-51000pcs/40ft-102000pcs
view detail
01

Door Sensor Valve LX-305

2021-07-22 19:14:08
Technical Parameters 1. Switches: ①Normally Closed ②Normally Open ③Chang Over 2. Contact power: ①10W ②3W ③3W 3. Current of switches: ①0.5A ②0.2A ③0.2A 4. Beginning voltage: ①100V ②30V ③30V 5. Initial resistance: 200? 6. Action distance: 18-23mm/20-25mm Packing Data Qty./ctn Carton Size Qty./Container 55 pcs 37.5X29.5X30cm 20ft-935000pcs/40ft-1870000pcs
view detail
01

Door Sensor Valve LX-304

2021-07-22 19:14:09
Technical Parameters  1. Switches: ①Normally Closed ②Normally Open ③Chang Over 2. Contact power: ①10W ②10W ③3W 3. Current of switches: ①0.5A ②0.5A ③0.2A 4. Beginning voltage: ①100V ②100V ③30V 5. Initial resistance: 200? 6. Action distance: 15-20mm/20-25mm Packing Data Qty./ctn Carton Size Qty./Container 60pcs 37.5X29.5X30 cm 20ft-510000pcs/40ft-1020000pcs
view detail
01

Door Sensor Valve LX-303

2021-07-22 19:14:10
Technical Parameters  1. Switches: ①Normally Closed②Normally Open③Chang Over 2. Contact power: ①10W ②3W ③3W 3. Current of switches: ①0.5A ②0.2A ③0.2A 4. Beginning voltage: ①100V ②30V ③30V 5. Initial resistance: 200? 6. Action distance: 35-45mm Packing Data Qty./ctn Carton Size Qty./Container 20 37.5X29.5X30 cm 20ft-425000pcs/40ft-850000pcs
view detail
01

Door Sensor Valve LX-302

2021-07-22 19:14:11
Technical Parameters  1. Switches: ①Normally Closed②Normally Open 2. Contact power: ①10W ②3W 3. Current of switches: ①0.5A ②0.2A 4. Beginning voltage: ①100V ②30V 5. Initial resistance: 200? 6. Action distance:20-25mm Packing Data Qty./ctn Carton Size Qty./Container 60 375X295X300 mm 20ft-1000000pcs/40ft-2000000pcs
view detail
01

Door Sensor Valve LX-301

2021-07-22 19:14:12
Technical Parameters 1. Frequency:315M 2. Chip: CS5211 3. Oscillation resistance: 4.7M 4. Launch distance: 1000M 5. The type of encoder: fixed encoder 6. Voltage:12V DC 7. working current:30mA 8. Static current:3mA Packing Data Qty./ctn Carton Size Qty./Container 56pcs 37.5X29.5X30cm 20ft-47600pcs/40ft-95200pcs
view detail
01

Conventional Control Panel LX-801-20

2021-07-22 19:14:13
Conventional Fire Alarm Control Panel  Model #: LX-801-20 Technical Parameters 1. Input voltage:240VAC±10% / 50/60Hz 2. Battery: 24VDC 3. Charging voltage protection: 1.6Ah glass fuse 4. Sounder output: 24V nominal EOL 10K resistor 5. Auxiliary contacts: 30VDC,1A max. NC/NO 6. Main supply protection: glass fuse 7. Sounder protection: 2x500mA glass fuse 8. Reverse battery protection: charger glass fuse 9. Zone EOL: 5.6K resistor 10. Zoned visual red alarm and yellow trouble indicators 11. Continuous signal during alarm 12. Built-in battery charger 13. Low / no power and battery detection 14. Automatic loading and testing of battery 15. Evacuate ( alarm resound) 16. LED test 17. Product size: 31 x44x9.6cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-801-20 2PCS 38X31.5X50CM 934PCS Parts Description
view detail
01

Conventional Control Panel LX-801-12

2021-07-22 19:14:14
Conventional Fire Alarm Control Panel  Model #: LX-801-12 Technical Parameters 1. Input voltage:240VAC±10% / 50/60Hz 2. Battery: 24VDC 3. Charging voltage protection: 1.6Ah glass fuse 4. Sounder output: 24V nominal EOL 10K resistor 5. Auxiliary contacts: 30VDC,1A max. NC/NO 6. Main supply protection: glass fuse 7. Sounder protection: 2x500mA glass fuse 8. Reverse battery protection: charger glass fuse 9. Zone EOL: 5.6K resistor 10. Zoned visual red alarm and yellow trouble indicators 11. Continuous signal during alarm 12. Built-in battery charger 13. Low / no power and battery detection 14. Automatic loading and testing of battery 15. Evacuate ( alarm resound) 16. LED test 17. Product size: 31 x32x9.6cm Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-801-12 2pcs 38x31.5X39CM 1198PCS Parts Description
view detail
01

Fire Siren LX-902

2021-07-22 19:14:15
Fire Siren  Model #: LX-902 Technical Parameters 1. Voltage: 24VDC (50mA) 2. Voltage: 12VDC (100mA) 3. Sound: 100dB ±5dB (at 24VDC,1 meter) 4. Tone: harmonic bell sound or sweep tone or siren sound 5. Operating current (at 24VDC): 22mA (bell only) 6. Material: ABS, red color 7. Product size: 8.2x8.2x3.3cm Packing Data QTY/CTN CARTON SIZE QTY/20GP 100pcs 47x32x38.5CM 57500pcs Parts Description
view detail
01

Manual Call Point LX-505

2021-07-22 19:14:16
Manual Call Point Model #: LX-505 Technical Parameters 1. Voltage range: 9V--24VDC 2. Static current: ≤10mA 3. Alarm current: ≤20mA 4. Operating temperature: -5℃ -- +65℃ 5. Working humidity: 10%--90% RH 6. Product size: 10.4x9.2 x5.6cm 7. Installation: indoor or dry occasion 8. LED indicator: in no-alarm state,green indicator flashing,when alarming red indicator shining Packing Data QTY/CTN CARTON SIZE QTY/20GP 100pcs 50x32x45.5CM 36100pcs Parts Description
view detail
01

Manual Call Point LX-503

2021-07-22 19:14:17
Technical Parameters 1. Voltage range: 12V--50VDC 2. Operating current: 3A 3. Operating temperature: -10℃ -- +65℃ 4. Working humidity range: 10%--90% RH 5. Product size: 10.4x9.2 x5.6cm 6. Installation: indoor or dry occasion 7. Push button panel material: glass, can't reuse Packing Data Item No. QTY/CTN CARTON SIZE QTY/20GP LX-503 100pcs 50x32x45.5 36100pcs
view detail
01

Manual Call Point LX-502

2021-07-22 19:14:18
Manual Call Point Model #: LX-502 Technical Parameters 1. Voltage range: 12V--50VDC 2. Operating current: 3A 3. Operating temperature: -10℃ -- +65℃ 4. Working humidity range: 10%--90% RH 5. Product size: 10.4x9.2 x5.6cm 6. Installation: indoor or dry occasion 7. Push button panel material: glass, can't reuse Packing Data QTY/CTN CARTON SIZE QTY/20GP 100pcs 50x32x45.5CM 36100pcs Parts Description
view detail